EFFECT OF CROWN-IMPLANT (C/I) RATIO OF SHORT IMPLANTS ON PERI-IMPLANT STRESS: A FINITE ELEMENT ANALYSIS

Main Article Content

NAIRA GHAMBARYAN DDS
CURD BOLLEN DDS, PHD, MSC
HARUTYUN HARUTYUNYAN
GAGIK HAKOBYAN DMSC, PHD

Abstract

Objectives. Purpose  of this study was to evaluate the distribution of peri-implant stress with different С/I ratio( 1.5:1, 1.75:1, 2:1) according to the von Mises criterion.


Materials and methods: Stress analysis was performed using Invesalius 3.0, Rhinoceros 3D 4.0 software. Three 3D models of the mandibular segment of the bone block were developed:



  • model A, a short implant C/I – 1,5:1;

  • model B, a short implant C/I -1.75:1;

  • model C, a short implant C/I -2:1.


Results: The results of the current study, indicate the increase in crown height showed little difference in load at the crown/implant interface with crown/implant ratios of 1.5:1, 1.75:1 and 2:1.


Conclusions: Study showed that short implantats for prosthetic rehabilitation can be considered favorable and well substantiated, C/I ratio is not so important for the effective functioning of short implants.

Article Details

Section
Articles

References

Cooper LF. A role for surface topography in creating and maintaining bone at titanium endosseous implants. J Prosthet Dent 2000; 84:522-534.

Winkler S, Morris HF, Ochi S. Implant survival to 36 months as related to length and diameter. Ann Periodontol 2000; 5:22-31.

Lee JH, Frias V, Lee KW, Wright RF. Effect of implant size and shape on implant success rates: a literature review. J Prosthet Dent 2005; 94:377-381.

Renouard F, Nisand D. Impact of implant length and diameter on survival rates. Clin Oral Implants Res 2006; 17:35-51.

Kotsovilis S, Fourmousis I, Karoussis IK, Bamia C. A systematic review and meta-analysis on the effect of implant length on the survival of rough-surface dental implants. J Periodontol 2009; 80:1700-1718.

Anitua E, Tapia R, Luzuriaga F, Orive G. Influence of implant length, diameter, and geometry on stress distribution: A finite element analysis Int J Periodontics Restorative Dent 2010;30:88-95.

Kitamura E, Stegaroiu R, Nomura S, Miyakawa O. Biomechanical aspects of marginal bone resorption around osseointegrated implants: considerations based on a three-dimensional finite element analysis. Clin Oral Impl Res 2004; 15:401-409

Dam VV, Trinh HA, Rokaya D, Trinh DH. Bone Augmentation for Implant Placement: Recent Advances. Int J Dent. 2022 Mar 27; 2022:8900940. doi: 10.1155/2022/8900940.

Kumar, V.V., Ebenezer, S., Thor, A. (2021). Bone Augmentation Procedures in Implantology. In: Bonanthaya, K., Panneerselvam, E., Manuel, S., Kumar, V.V., Rai, A. (eds) Oral and Maxillofacial Surgery for the Clinician. Springer, Singapore. https://doi.org/10.1007/978-981-15-1346-6_19

Kim YK, Ku JK. Ridge augmentation in implant dentistry. J Korean Assoc Oral Maxillofac Surg. 2020 Jun 30;46(3):211-217. doi: 10.5125/jkaoms.2020.46.3.211

Anitua E, Alkhraisat MH, Orive G. Novel technique for the treatment of the severely atrophied posterior mandible. Int J Oral Maxillofac Implants. 2013 Sep-Oct;28(5):1338-46. doi: 10.11607/jomi.3137.

Len Tolstunov. Essential Techniques of Alveolar Bone Augmentation in Implant Dentistry: A Surgical Manual;2022; Online ISBN:9781119827351 |DOI:10.1002/9781119827351

Schaaf, H., Lendeckel, S., Howaldt, H. P., & Streckbein, P. Donor site morbidity after bone harvesting from the anterior iliac crest. Oral Surgery, Oral Medicine, Oral Pathology, Oral Radiology, and Endodontology.2010;109(1):52-58.

Li J, Wang HL. Common implant-related advanced bone grafting complications: classification, etiology, and management. Implant Dent. 2008;17(4):389-401.

David Reininger, Carlos Cobo-Vázquez, Marta Monteserín-Matesanz, Juan López-Quiles Complications in the use of the mandibular body, ramus and symphysis as donor sites in bone graft surgery. A systematic review Med Oral Patol Oral Cir Bucal. 2016; 1;21 (2):241-249.

M. Saad, A. Assaf, E. Gerges.The Use of Narrow Diameter Implants in the Molar Area. International Journal of Dentistry Volume 2016, Article ID 8253090; https://doi.org/10.1155/2016/8253090

Grant BT, Pancko FX, Kraut RA. Outcomes of placing short dental implants in the posterior mandible: a retrospective study of 124 cases. J Oral Maxillofac Surg 2009; 67:713-717.

Jain N, Gulati M, Garg M, Pathak C. Short Implants: New Horizon in Implant Dentistry. J Clin Diagn Res. 2016 Sep;10(9): ZE14-ZE17. doi: 10.7860/JCDR/2016/21838.8550.

Antiua E, Escuer V, Alkhraisat MH. Short Narrow Dental Implants versus Long Narrow Dental Implants in Fixed Prostheses: A Prospective Clinical Study. Dent J (Basel). 2022 Mar 4;10(3):39. doi: 10.3390/dj10030039.

Romeo E, Bivio A, Mosca D, Scanferla M, Ghisolfi M, Storelli S. The use of short dental implants in clinical practice: literature review. Minerva Stomatol. 2010 Jan-Feb;59(1-2):23-31. PMID: 20212407.

Nedir, R.; Bischof, M.; Briaux, J.-M.; Beyer, S.; Szmukler-Moncler, S.; Bernard, J.-P. A 7-year life table analysis from a prospective study on ITI implants with special emphasis on the use of short implants. Clin. Oral Implants Res. 2004; 15:150–157.

Karthikeyan I, Desai SR, Singh R. Short implants: A systematic review. J Indian Soc Periodontol. 2012 Jul;16(3):302-312. doi: 10.4103/0972-124X.100901.

Panos Papaspyridakos, Andre De Souza , Konstantinos Vazouras, Hadi Gholami , Sarah Pagni, Hans-Peter Weber,Survival rates of short dental implants (≤6 mm) compared with implants longer than 6 mm in posterior jaw areas: A meta-analysis Clin Oral Impl Res. 2018;29(Suppl. 16):8–20.

Alysson-Henrique-Neves Ramos, G. M., Cornacchia, E. N., Mauricio-Greco Cosso, L. N. D., & Souza, E. G. Z. Extra short 4mm implants used to rehabilitation of atrophic posterior mandible. A serial case reports. Journal of Clinical and Experimental Dentistry, 2020;12(5): 519.

Anitua, E., Piñas, L., & Orive, G. Retrospective study of short and extra‐ short implants placed in posterior regions: influence of crown to implant ratio on marginal bone loss. Clinical implant dentistry and related research.2015; 17(1):102-110

Gürlek, Ö., Kaval, M. E., Buduneli, N. U. R. C. A. N., & Nizam, N. E. J. A. T. Extra‐ short implants in the prosthetic rehabilitation of the posterior maxilla. Australian dental journal. 2019;64(4):353-358.

Silva R, Villalón P, Cáceres F. Effect of macro-design in the primary stability of short and extra-short implants using resonance frequency analysis. An ex vivo study. J Oral Biol Craniofac Res. 2020 Oct-Dec;10(4):603-607. doi: 10.1016/j.jobcr.2020.08.020.

Ravida A, Barootchi S, Askar H, Suarez-Lopez Del Amo F, Tavelli L, Wang HL. Long-term effectiveness of extra-short (≤6 mm) dental implants: a systematic review. Int J Oral Maxillofac Implants. 2019; 34:68-84. doi:10.11607/jomi.6893

Blanes RJ. To what extent does the crown-implant ratio affect the survival and complications of implant-supported reconstructions? A systematic review. Clin Oral Impl Res 2009; 20:67-72.

Francesco G Mangano,Irene Frezzato,Alberto Frezzato,Giovanni Veronesi,Carmen Mortellaro,Carlo Mangano.The Effect of Crown-to-Implant Ratio on the Clinical Performance of Extra-Short Locking-Taper Implants.The Journal of craniofacial surgery.2016; 27(3); DOI:10.1097/SCS.0000000000002562

Schulte J, Flores AM, Weed M. Crown-to-implant ratios of single tooth implant supported restorations. J Prosthet Dent 2007; 98:1-5.

Birdi H, Schulte J, Kovacs A, Weed M, Chuang SK. Crown-to-implant ratios of short-length implants. J Oral Implantol. 2010;36(6):425-33. doi: 10.1563/AAID-JOI-D-09-00071.

Bulaqi HA, Mashhadi MM, Safari H, Samandari MM, Geramipanah F. Effect of increased crown height on stress distribution in short dental implant components and their surrounding bone: a finite element analysis. J Prosthet Dent. 2015; 113:548–557.

Andrea Torres-Alemany, Lucía Fernández-Estevan, * Rubén Agustín-Panadero, José María Montiel-Company, Carlos Labaig-Rueda, and José Félix Mañes-Ferrer.Clinical Behavior of Short Dental Implants: Systematic Review and Meta-AnalysisJ Clin Med. 2020 Oct; 9(10): 3271. doi: 10.3390/jcm9103271

Tang, C., Du, Q., Luo, J. et al. Simultaneous placement of short implants (≤ 8 mm) versus standard length implants (≥ 10 mm) after sinus floor elevation in atrophic posterior maxillae: a systematic review and meta-analysis. Int J Implant Dent.2022;8,45 https://doi.org/10.1186/s40729-022-00443-1

Chaware, Sachin Haribhau; Thakare, Vrushali1; Chaudhary, Ritu2; Jankar, Ajit3; Thakkar, Smruti; Borse, Sidesh.The rehabilitation of posterior atrophic maxilla by using the graftless option of short implant versus conventional long implant with sinus graft.A systematic review and meta-analysis of randomized controlled clinical trial The Journal of Indian Prosthodontic Society.2021; 21(1):28-44.DOI: 10.4103/jips.jips_400_20

Pinar Ercal1 & Aysegul Erten Taysi1 & Demet Cagil Ayvalioglu2 & Meltem Mert Eren3 & Soner Sismanoglu. Impact of peri-implant bone resorption, prosthetic materials, and crown to implant ratio on the stress distribution of short implants: a finite element analysis. Medical & Biological Engineering & Computing.2021;59:813–824 https://doi.org/10.1007/s11517-021-02342-w / Published online: 17 March 2021 M

Reddy MS, Sundram R, Eid Abdemagyd HA. Application of Finite Element Model in Implant Dentistry: A Systematic Review. J Pharm Bioallied Sci. 2019 May;11(Suppl 2):S85-S91. doi: 10.4103/JPBS.JPBS_296_18.

Reddy, M Sesha,Sundram, Rajasekar,Eid Abdemagyd, Hossam Abdelatty. Application of Finite Element Model in Implant Dentistry.A Systematic Review.Journal of Pharmacy And Bioallied Sciences.2019.11( 2):85-91, OI: 10.4103/JPBS.JPBS_296_18

Nour M.T. Ajaj AL-Kordy1 Mohannad H. AL-Saadi.Finite Element Study of Stress Distribution with Tooth-Supported Mandibular Overdenture Retained by Ball Attachments or Resilient Telescopic Crowns European Journal of Dentistry © 2022.,doi.org/ 10.1055/s-0042-1749363

Aldiéris Alves Pesqueira, at.al Use of Stress Analysis Methods to Evaluate the Biomechanics of Oral Rehabilitation With Implants .J Oral Implantol .2014;40(2):217–228. https://doi.org/10.1563/AAID-JOI-D-11-00066

Albrektsson T, Donos N, Working Group 1. Implant survival and complications. The third EAO consensus conference 2012. Clin Oral Implants Res. 2012; 23(6): 63- 65. doi:10.1111/j.1600-0501.2012.02557.x

Esfahrood ZR, Ahmadi L, Karami E, Asghari S. Short dental implants in the posterior maxilla: a review of the literature. J Korean Assoc Oral Maxillofac Surg. 2017;43(2):70-76. doi: 10.5125/jkaoms.2017.43.2.70.

da Rosa T, de Souza P, Binhame Albini Martini M, Reis A-AL. Do short implants have similar survival rates compared to standard implants in posterior single crown?: a systematic review and meta-analysis. Clin Implant Dent Relat Res. 2018; 20(5): 890- 901. doi:10.1111/cid.12634

Ravidà A, Wang IC, Barootchi S, et al. Meta-analysis of randomized clinical trials comparing clinical and patient-reported outcomes between extra-short (≤6 mm) and longer (≥10 mm) implants. J Clin Periodontol. 2019; 46(1): 118- 142. doi:10.1111/jcpe.13026

Sadowsky SJ. Occlusal overload with dental implants: a review. Int J Implant Dent. 2019 Jul 23;5(1):29. doi: 10.1186/s40729-019-0180-8.

Liu, W.K., Li, S. & Park, H.S. Eighty Years of the Finite Element Method: Birth, Evolution, and Future. Arch Computat Methods Eng 29, 4431–4453 (2022). https://doi.org/10.1007/s11831-022-09740-9

Moraes SL, Verri FR, Santiago Jr JF, Almeida DA, de Mello CC, Pellizzer EP. A 3-D finite element study of the influence of crown-implant ratio on stress distribution. Braz Dent J 2013;24:635-641.

Faria Almeida DA, Pellizzer EP, Verri FR, Santiago Jr JF, Carvalho PS. Influence of tapered and external hexagon connections on bone stresses around tilted dental implants: Three-dimensional finite element method with statistical analysis. J Periodontol 2014; 85:261- 269

Araki H, Nakano T, Ono S, Yatani H. Three-dimensional finite element analysis of extra short implants focusing on implant designs and materials. Int J Implant Dent. 2020 Jan 29;6(1):5. doi: 10.1186/s40729-019-0202-6.

Zupancic Cepic L, Frank M, Reisinger A, Pahr D, Zechner W, Schedle A. Biomechanical finite element analysis of short-implant-supported, 3-unit, fixed CAD/CAM prostheses in the posterior mandible. Int J Implant Dent. 2022 Feb 11;8(1):8. doi: 10.1186/s40729-022-00404-8.

Blanes RJ, Bernard JP, Blanes ZM, Belser UC. A 10-year prospective study of ITI dental implants placed in the posterior region. II: Influence of the crown-to-implant ratio and different prosthetic treatment modalities on crestal bone loss. Clin Oral Implants Res. 2007 Dec;18(6):707-14. doi: 10.1111/j.1600-0501.2006.01307.x.

Tawil G, Aboujaoude N, Younan R. Influence of prosthetic parameters on the survival and complication rates of short implants. Int J Oral Maxillofac Implants. 2006;21:275-82.

Schulte J, Flores AM, Weed M. Crown-to-implant ratios of single tooth implant supported restorations. J Prosthet Dent. 2007;98:1-5.

Ghambaryan N; Tunyan G, Jilavyan A, Khachatryan G, Mathevosyan D, Hakobyan G. Evaluation of the survival rate of short implants placed in the posterior atrophic mandible: 5-year clinical study. Quintessence Int. 2022 Aug 17;53(8):690-696. doi: 10.3290/j.qi.b3095013.

Ghambaryan, N., Jilavyan, A., Burnazyan, S. et al. Clinical Outcome of Immediate Loading UV-Photofunctionalized Implants in Patients with Completely Edentulous Mandible, Placed with Guided Surgery. J. Maxillofac. Oral Surg. 2023; 22 (1), 64–75 https://doi.org/10.1007/s12663-022-01798-z

Ghambaryan N. Impact of Dental Implant Surface UV-photofunctionalization on Osseointegration and Antibacterial Properties: Systematic Review. Bulletin of Stomatology and Maxillofacial Surgery. 2024;20(2):152-160. doi:10.58240/1829006X-2024.2-152

Ghambaryan, N., Yessayan, L. & Hakobyan, G. Long-term effectiveness of UV functionalised short (≤ 6 mm) dental implants placed in the posterior segments of the atrophied maxilla: controlled case series. Odontology.2024.112,1316–1325 https://doi.org/10.1007/s10266-024-00926-0